13
55A max. when AC input 115Vac at 25
cold start.
110A max. when AC input 230Vac at 25
cold start.
Inrush Current:
80% (min.) at full load (typical) and 115Vac input
Power Efficiency
1.Conducted EMI
•Meet FCC: Class B
•Meet CISPR 2 2: Class B
•Meet BSMI: Class B
2.Safety Standards
•Meet CUL (UL 60950)
•Meet TUV En60950
•Meet CB (IE C 950)
•Meet CE
3.Harmonic Meet IEC1000-3-2, Class D
CE Requirements
No DC output. The fan or fans are motionless. Check:
•Is the AC inlet plug firmly plugged into the PSU inlet socket?
•Is the wall socket, extension power cord, power strip or surge protector in use, fully
functional and wall power switch turned ‘ON’?
•Is the Main Board socket (20+4 pin) plug fully and firmly inserted?
Condition 1:
The fan or fans began rotating and then stopped. The system hangs without
proceeding any further. Check:
•Are the peripheral connectors firmly plugged into accessory devices, such as the
main hard drive, CD ROM, etc?
•If a plug has been inadvertently connected in an off-set or reversed position, unplug
the AC power source, reconnect the offending connectors and then wait for 30
seconds before replug in the AC power source and try again.
Note: If the power supply is still unable to power up after following the above
instruction, please send the unit back to your dealer or retailer for after sales
service.
Condition 2: